COMMAND OVERVIEW
13/10/2016 Version No. 001
147
Parameter/
Return parameter
ABS
The test results are judged from absolute
values.
DPER
The test results are judged from a
reference value ± a percentage offset.
(delta percent)
Example
CALC:SCAN:LIM:MODE ABS
Sets compare mode to absolute values.
CALCulate:SCAN:LIMit:REFerence
Set
Query
Description
Sets or returns the reference limit for the scan function.
Syntax
Query Syntax
CALCulate:SCAN:LIMit:REFerence {<NRf>[,<String>]}
CALCulate:SCAN:LIMit:REFerence?
Parameter
<NRf>
000.0001~999.9999
<String>
mohm/ohm/kohm/maohm,unit
If unit is not set,the unit will be
automatically set by the present range.
Return parameter
<NR3>
000.0001~999.9999E±X