Switcher Sets
The switcher stores configuration and operation data
in a number of registers that contain the individual
entries for items such as memories or personality
settings. These registers can be stored as a single
archive file, or as a register set that contains all the
individual register of that type; all memories for
example. These files are stored into Sets on USB drive.
Different Sets can be created for different shows or
applications, allowing you to quickly locate and recall
the switcher configurations.
The switcher stores information in the following
registers:
•
Memory
— contains all the memories for ME,
MiniME
™
, and chroma keys.
•
Custom Control
— contains all the custom control
banks and macros.
•
Personality
— contains all the user interface
settings, such as transition rates, that are stored
under the
PERS
menu. Some personality settings
are specific to the control panel and can be stored
independently if you are working with a MultiPanel
system.
•
Installation
— contains all the external device
setup, and software settings for the switcher.
To Store a Set
Switcher Sets can only be stored to a USB drive. The
USB drive must be present before you try to store the
Set. A total of 10 Sets of switcher setup information
can be stored onto the same USB drive.
1.
Insert a USB drive into the USB Port on the
switcher. You must wait 5 seconds for the switcher
to recognise the USB drive.
2.
Press
MENU
>
SAVE
.
3.
Use the
All
knob to select the set (
0-9
) you want
to store the switcher registers to.
4.
Press the knob to select the registers you want to
store to the selected set. If an (*) is shown on the
menu, that register already exist in the set and will
be overwritten.
•
All
— store all registers to the set.
•
Mems
— store only the memory registers to
the set.
•
Cust
— store only the custom control
registers to the set.
•
Inst
— store only the installation registers to
the set.
•
Pers
X
— store only the personality registers
to the set. Use the
Pers
knob to select whether
to include the personality setting for all
panels (
PersA
) or only the current panel
(
PersM/1/2
).
5.
Press
Confrm
.
To Load a Set
Switcher Sets can only be loaded from a USB drive.
The USB drive must be present before you try to load
the settings.
1.
Insert your USB drive into the USB Port on the
switcher. You must wait 5 seconds for the switcher
to recognise the USB drive.
2.
Press
MENU
>
LOAD
.
3.
Use the
All
knob to select the set (
0-9
) you want
to load the switcher registers from.
4.
Press the selected set. Only registers with an (*)
shown on the menu exist in the set.
•
All
— recall all registers from the set.
•
Mems
— recall only the memory registers
from the set.
•
Cust
— recall only the custom control
registers from the set.
•
Inst
— recall only the installation registers
from the set.
•
Pers
— recall only the personality registers
from the set. Use the
Pers
knob to select
whether to include the personality setting for
all panels (
PersA
) or only a specific panel
(
PersM/1/2
).
5.
Press
Confrm
.
Carbonite Black Operation Manual (v14.0) — Switcher Sets •