VLT
®
8000 AQUA
■
General technical data
Line supply (L1, L2, L3):
Supply voltage 200-240 V units ....................................................................... 3 x 200/208/220/230/240 V ±10%
Supply voltage 380-480 V units ................................................................ 3 x 380/400/415/440/460/480 V ±10%
Supply voltage 525-600 V units .............................................................................. 3 x 525/550/575/600 V ±10%
Supply frequency ......................................................................................................................... 50/60 Hz +/- 1%
Max. imbalance of supply voltage: .........................................................................................................................
VLT 8006 - 8011 AQUA / 380 - 480 V and VLT 8002 - 8011 AQUA / 525 - 600 V
±2.0% of rated supply voltage
VLT 8016 - 8072 AQUA / 525 - 600 V, 380 - 480 V and
VLT 8006 - 8032 AQUA / 200 - 240 V .................................................................
±1.5% of rated supply voltage
VLT 8100 - 8300 AQUA / 525 - 600 V, VLT 8102 - 8600 AQUA / 380 - 480 V and
VLT 8042 - 8062 AQUA / 200 - 240 V .................................................................
±3.0% of rated supply voltage
Displacement factor / cos.
ϕ
..................................................................................................... near unity (> 0.98)
True Power Factor (
λ
) ................................................................................................... nominal 0.90 at rated load
Input Line (L1, L2, L3) Allowable On-OFF Switching Sequnces ........................................... approx. 1 time/2 min.
Max. short-circuit current ........................................................................................................................... 100 kA
VLT output data (U, V, W):
Output voltage ................................................................................................................ 0-100% of supply voltage
Output frequency 8006-8032, 200-240V ............................................................................ 0 - 120 Hz, 0-1000 Hz
Output frequency 8042-8062, 200-240V .............................................................................. 0 - 120 Hz, 0-450 Hz
Output frequency 8072-8600, 380-460V .............................................................................. 0 - 120 Hz, 0-450 Hz
Output frequency 8002-8016, 525-600V ............................................................................ 0 - 120 Hz, 0-1000 Hz
Output frequency 8022-8062, 525-600V .............................................................................. 0 - 120 Hz, 0-450 Hz
Output frequency 8072-8300, 525-600V .............................................................................. 0 - 120 Hz, 0-450 Hz
Rated motor voltage, 200-240 V units ............................................................................. 200/208/220/230/240 V
Rated motor voltage, 380-480 V units ...................................................................... 380/400/415/440/460/480 V
Rated motor voltage, 525-600 V units ............................................................................................ 525/550/575 V
Rated motor frequency ............................................................................................................................ 50/60 Hz
Switching on output ................................................................................................................................ Unlimited
Ramp times ....................................................................................................................................... 1- 3600 sec.
Torque characteristics:
Starting torque .............................................................................................................................. 110% for 1 min.
Starting torque (parameter 110
High break-away torque
) ..................................... Max. torque: 130% for 0.5 sec.
Acceleration torque ........................................................................................................................................ 100%
Overload torque ............................................................................................................................................. 110%
Control card, digital inputs:
Number of programmable digital inputs ................................................................................................................ 8
Terminal nos. .......................................................................................................... 16, 17, 18, 19, 27, 29, 32, 33
Voltage level ......................................................................................................... 0-24 V DC (PNP positive logics)
Voltage level, logical "0" .......................................................................................................................... < 5 V DC
Voltage level, logical "1" ........................................................................................................................ > 10 V DC
Maximum voltage on input ....................................................................................................................... 28 V DC
Input resistance, R
i
........................................................................................................................... approx. 2 k
Scanning time per input ............................................................................................................................ 3 msec.
MG.80.A7.22 - VLT is a registered Danfoss trademark
28
Rosewood STP ST42 General (Operation and Maintenance Manual - Part 4:
Section 6.3 Manufacturers Manuals 6.3.33 Danfoss VLT Aquadrive 8000) Vendor Manual
QP Id: VM207
Active: 03/09/2013