Werferbetrieb
Turret Operation
Turret RM 24 M - Foam operation with CAFS
- Operate pump as mentioned in the
◊
"Tank Suction Operation" or
◊
"Drafting Operation from Open Water Source" or
◊
"Supply Operation / Hydrant Operation" chapter.
- Direct the turret to desired position.
- Uncouple the aspirating nozzle (9) and connect nozzle (7),
which is located on the vehicle´s roof, to the turret.
- Operate pump as mentioned in the
◊
"Foam Operation wich CAFS" chapter.
- Open CAFS turret valve:
◊
Toch switch (S5) to "
1
/
2
2
o´clock
" position.
Note:
The CAFS NP-outlets right hand side will be closed automatically
as soon as the CAFS turret valve is open.
- The pump pressure and throwing range can be adjusted to the
desired value by using switch (S9) or manually by the machinist.
- For further operation details please refer to separate operation
manual of turret RM 24 M.
Werfer RM 24 M - Schaumbetrieb mit CAFS
- Pumpenanlage wie im Kapitel
◊
"Tanksaugbetrieb" oder
◊
"Ansaugen von offener Wasserstelle" oder
◊
"Hydrantenbetrieb / Einspeisbetrieb" beschrieben, betreiben.
- Werfer in Angriffsstellung bringen.
- Hohlstrahldüse (9) abkuppeln und das am Dach gehalterte
Vollstrahlrohr (7) am Werfer ankuppeln.
- Pumpenanlage wie im Kapitel
◊
"Schaumbetrieb mit CAFS" beschrieben, betreiben.
- CAFS Werferventil öffnen:
◊
Schalter (S5) auf Position "
1
/
2
2
UHR
" antasten.
Hinweis:
Die seitlichen CAFS Druckabgänge werden automatisch geschlos-
sen, sobald das CAFS Werferventil geöffnet ist.
- Pumpendruck und Wurfweite mittels Schalter (S9) oder durch
den Maschinisten auf den gewünschten Wert erhöhen.
- Weitere Bedienungschritte entnehmen Sie bitte der separaten
Betriebsanleitung für RM 24 M.