2.6.8 Timing chart
(A4 single copying in the platen cover mode)
The transfer output time is longer than separation output
time because the residual potential is measured for the
process control. The vacuum fan continues to run for 30
minutes by a timer after the main switch is turned OFF.
2.6.9 Error reset
SC11
Transfer leak
SC12
Separation leak
Deteriorated or broken wire.
When a transfer or separation leakage occurs first time, the paper feed jam indicator (loca-
tion A) stays ON on the display panel. (In case of a real paper jam, the indicator blinks, but it
does not stay ON.) This is not counted as a paper feed jam in the logging data, but is
counted as an SC in the [3-07] screen. After that, SC11 (or SC12) will be indicated on the
display panel if the leakage occurs more two times (three times total) in 100 copies.
1 July 1994
Image Transfer and Paper Separation
2-51
Содержание PCU10
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 36: ...SECTION 2 SECTIONAL DESCRIPTIONS...
Страница 46: ...2 1 11 Paper feed operation Circuit diagram Paper Feed 1 July 1994 2 10...
Страница 59: ...2 2 7 Optics operation Circuit diagram 1 July 1994 Optics 2 23...
Страница 69: ...2 3 9 OPC unit operation Circuit diagram 1 July 1994 OPC Unit 2 33...
Страница 76: ...2 4 5 Charging operation Circuit diagram OPC Charge 1 July 1994 2 40...
Страница 82: ...2 5 4 Eraser operation Circuit diagram Erase 1 July 1994 2 46...
Страница 86: ...2 6 7 Transfer separation operation Circuit diagram Image Transfer and Paper Separation 1 July 1994 2 50...
Страница 94: ...2 7 7 Cleaning unit operation Circuit diagram Cleaning 1 July 1994 2 58...
Страница 100: ...2 8 7 Timing chart OPC Filming Removal 1 July 1994 2 64...
Страница 106: ...2 9 11 Development operation Circuit diagram Development 1 July 1994 2 70...
Страница 121: ...2 11 3 Process control flow 1 July 1994 Process Control 2 85...
Страница 138: ...2 13 9 Duplex exit operation Circuit diagram Duplex and Paper Exit 1 July 1994 2 102...
Страница 152: ...2 14 8 Timing chart SADF mode Condition Two A4 copies from an A4 original ADF 1 July 1994 2 116...
Страница 153: ...Single side original mode with sort stack mode Condition One A4 copy each from three originals 1 July 1994 ADF 2 117...
Страница 154: ...Duplex original mode with stack mode Condition One A4 copy from one original ADF 1 July 1994 2 118...
Страница 156: ...ADF 1 July 1994 2 120...
Страница 161: ...Exit sensor 1 July 1994 ADF 2 125...
Страница 162: ...2 14 10 ADF operation Circuit diagram ADF 1 July 1994 2 126...
Страница 178: ...2 16 9 LCT operation Circuit diagram Large Capacity Tray 1 July 1994 2 142...
Страница 179: ...DC drive board paper feed motor DC drive board DC motor AC 230V 1 July 1994 Large Capacity Tray 2 143...