2.14 ADF
2.14.1 Main construction
Structure diagram
Construction
ADF unit
Original is set by the original stopper and original guides.
SADF unit
Original is set by the original guides.
ADF unit
Position detecting system using the original stopper and
original guides.
SADF unit
Original guide position detecting system.
Original feed cycle end detecting, using the recycle arm.
Air knife separation and paper feed system by air
suction.
Consists of paper feed, intermediate transport, transport
belt, and reverse units.
Driven by 3 motors, 1 clutch and 12 timing belts.
Switchback roller
2nd reverse sensor
1st reverse
sensor
SADF exit
sensor
Reverse
entrance
roller
SADF exit
roller
Reverse exit
roller
SADF exit
gate plate
Reverse junction gate pawls
Original
feed roller
Antistatic
brush
Relay
rollers
1st transport
sensor
Exposure glass
Transport belt
Original size sensor
Relay rollers
2nd
transport
sensor
Antistatic
brush
SADF registration
gate plate
Registration sensor
SADF entrance gate plate
SADF set
sensor
Right turn roller
Original length
sensor
Original stopper
Original guides
Original transport belt
Recycle arm sensor
Original set sensor
Exit sensor
Exit roller
Recycle arm height
sensor
Entrance sensor
ADF left cover
safety switch
ADF
Original setting
Original size detection
Original feed cycle end detection
Original separation and feed
Transport mechanism
Drive mechanism
1 July 1994
ADF
2-107
Содержание PCU10
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION...
Страница 36: ...SECTION 2 SECTIONAL DESCRIPTIONS...
Страница 46: ...2 1 11 Paper feed operation Circuit diagram Paper Feed 1 July 1994 2 10...
Страница 59: ...2 2 7 Optics operation Circuit diagram 1 July 1994 Optics 2 23...
Страница 69: ...2 3 9 OPC unit operation Circuit diagram 1 July 1994 OPC Unit 2 33...
Страница 76: ...2 4 5 Charging operation Circuit diagram OPC Charge 1 July 1994 2 40...
Страница 82: ...2 5 4 Eraser operation Circuit diagram Erase 1 July 1994 2 46...
Страница 86: ...2 6 7 Transfer separation operation Circuit diagram Image Transfer and Paper Separation 1 July 1994 2 50...
Страница 94: ...2 7 7 Cleaning unit operation Circuit diagram Cleaning 1 July 1994 2 58...
Страница 100: ...2 8 7 Timing chart OPC Filming Removal 1 July 1994 2 64...
Страница 106: ...2 9 11 Development operation Circuit diagram Development 1 July 1994 2 70...
Страница 121: ...2 11 3 Process control flow 1 July 1994 Process Control 2 85...
Страница 138: ...2 13 9 Duplex exit operation Circuit diagram Duplex and Paper Exit 1 July 1994 2 102...
Страница 152: ...2 14 8 Timing chart SADF mode Condition Two A4 copies from an A4 original ADF 1 July 1994 2 116...
Страница 153: ...Single side original mode with sort stack mode Condition One A4 copy each from three originals 1 July 1994 ADF 2 117...
Страница 154: ...Duplex original mode with stack mode Condition One A4 copy from one original ADF 1 July 1994 2 118...
Страница 156: ...ADF 1 July 1994 2 120...
Страница 161: ...Exit sensor 1 July 1994 ADF 2 125...
Страница 162: ...2 14 10 ADF operation Circuit diagram ADF 1 July 1994 2 126...
Страница 178: ...2 16 9 LCT operation Circuit diagram Large Capacity Tray 1 July 1994 2 142...
Страница 179: ...DC drive board paper feed motor DC drive board DC motor AC 230V 1 July 1994 Large Capacity Tray 2 143...