~DESCRIPTIONS OF FUNCTION CODE SETTINGS~
- 50 -
±11 : speed search from the set frequency
±12 : inhibition command for acceleration and deceleration
(refer to the descriptions of multiple level acc/dec time)
c. UP/DOWN command
± 13: UP command
± 14: DOWN command
± 15: clear UP/DOWN frequency command (frequency command
clear to 0.00 Hz)
>
0.1Sec
Speed search command by input terminals (F_053 = 11)
External RUN command
(FWD)
Speed search command
(X2)
Output frequency
Setting frequency
Output voltage
Current speed tracking
Output current
Time interval for
speed tacking (F_089)
V/F pattern of
speed tracking
(F_090)
Current for
speed tracking
(F_088)
Resume V/F pattern
Normal acceleration
time
Deceleraion time is 2 sec