~DESCRIPTIONS OF FUNCTION CODE SETTINGS~
- 36 -
J.
F_ 134
: Selections of resumption of factory setting
This function is used to resume the factory settings and store/write
settings between inverter and KP-201C. This is the last item of the
function.
Note:
The codes
and
are copy function to be
used for the case of several inverters with the same
settings.(Ref.Page22)
: Useless
: Clear fault records
: Resume the factory settings of 60 Hz.
: Resume the factory settings of 50 Hz.
: Store settings
: Resume last settings
: Digital keypad (KP-201C)
←
inverter parameters
: Digital keypad (KP-201C)
→
inverter parameters
H.
F_007
: Speed constant
The range of setting is 0.00~500.00 to set the value of MPM
displayed on keypad Line velocity = speed constant(F_007)
×
output frequency, which is the value of MPM, displayed in the
monitor mode.
I.
F_008
: No. decimal of speed display
Increasing the no. decimal to display the monitored signal more
precisely. The range of F_008 is 0~3.
Note : that any display can be set to be the main display, and that if
the keypad has not been operated and the auxiliary display
has been displayed for about 3 minutes, the main display is
shown.