~INSTALLATIONS AND CONFIRMATIONS~
- 6 -
D.
Cleaning of environment
The ventilation, cleanliness and moisture of the space in which the
inverter is installed have to be considered.
E.
Operator
Only experienced peoples can perform operation and trouble
shooting.
(3) Descriptions of terminals and wiring diagram
A.
Wiring diagram
Note that the terminals represented by and are denoted for main
and control circuits, respectively.
a. Wiring diagram for 1/2~5 HP(200V class)
/
1~5HP(400V class)
※
Built-in brake transistor
Terminals of main circuit
3-phase power source
(Single-phase connect
to R,S)
Forward
Vin frequency command
(DC 0~10V)
Induction motor
Grounding
Analog signal
output
(DC 0~10V)
Multi-function
output terminals
(relay output)
(AC 250V/0.5A
COS
θ
=0.3)
Multi-function
output terminals
(open collector)
(DC 48V/50mA)
RM5G/5P
R
S
T
R
S
T
FWD
REV
Tc1
Tb1
Ta1
Tc2
Ta2
GND
FM+
AM+
U
V
W
PE
P
PR
Braking Resistor(option)
IM
VR 1K
Ω
,1/4W
DSW1
I
V
P
P
P
Shielded
P
Terminals of control circuit
Reverse
Multi-function input terminal 1
Multi-function input terminal 2
Multi-function input terminal 3
Multi-function input terminal 4
Multi-function input terminal 5
Multi-function input terminal 6
Iin frequency command
(DC 4~20mA)
X1
X2
X3
X4
X5
X6
COM
12V(3)
Vin(2)
Iin
GND(1)
Y1
Y2
CME
Twisted-pair shielded wires