~APPENDIX A~
- 83 -
(5) Selections of AC reactor (ACL)
A. If the capacity of the power
source is greater than that of
inverter, an ACL has to be
installed in the R, S and T
terminals.
B. If the source power, supplying for inverter, is also for SCR, high
rated power motor or welding machine, ACL is needed.
C. In the case of several inverters are used simultaneously, ACL is
needed to avoid interference and improve the quality of
electricity for harmonics.
D. The specifications, determined according to the rated power of
motor used, are shown in following table.
Capacity of
power source
4000
600
0
60
400
ACL is needed
ACL is not needed
Rated power of inverter
(HP/KW/KVA) (mH) (A) (mH) (A) (HP/KW/KVA) (mH) (A) (mH) (A)
0.5/0.4/1.3
0.4
15
0.4
15
1/0.75/1.9
0.4
15
0.4
15
1/0.75/2
0.4
15
0.4
15
2/1.5/3.3
0.4
15
0.4
15
2/1.5/3
0.4
15
0.4
15
3/2.2/4
0.4
15
0.4
15
3/2.2/4
0.4
15
0.3
30
5/3.7/7
0.4
15
0.55
22
5/3.7/6
0.3
30
40
7.5/5.5/10
0.55
22
0.55
22
7.5/5.5/9
0.26
40
0.26
40
10/7.5/14
0.55
22
0.26
40
10/7.5/13
0.26
40
0.16
75
15/11/18
0.26
40
0.26
40
15/11/18
0.16
75
0.16
75
20/15/23
0.26
40
0.16
75
20/15/22
0.16
75
0.09 110
25/18.5/30
0.16
75
0.16
75
25/18.5/28
0.09 110
0.06 180
30/22/34
0.16
75
0.09 110
30/22/33
0.06 180
0.06 180
40/30/46
0.09 110
0.09 110
40/30/44
0.06 180
0.04 300
50/37/56
0.09 110
0.09 110
50/37/55
0.04 300
0.04 300
60/45/66
0.09 110
0.06 180
60/45/67
0.04 300
0.04 300
75/55/84
0.06 180
0.06 180
75/55/84
0.04 300
0.02 560
100/75/104
0.06 180
0.04 300
100/75/115
0.02 560
0.02 560
125/90/134
0.04 300
0.04 300
125/90/132
0.02 560
0.02 560
150/110/165
0.04 300
0.04 300
150/110/160
0.02 560
0.01 850
175/132/193
0.04 300
0.02 560
-
-
-
-
-
200/160/232
0.02 560
0.02 560
-
-
-
-
-
250/200/287
0.02 560
0.02 560
-
-
-
-
-
300/220/316
0.02 560
0.01 850
-
-
-
-
-
420/315/445
0.01 850
0.01 850
0.26
Continuous
rated power
200V series
Continuous
rated power
400V series
INPUT(RST) OUTPUT(UVW)