SE4000 MPEG-2 Contribution Encoder
Using a Remote Unit
01-0934-401-B
4-5
Query commands are issued by typing the command, without a parameter, and pressing Enter.
The SE4000 responds to the query by displaying information on the remote display.
For example, to query the remote port baud rate, issue the command
MC BAUD
and press
Enter. In this example:
•
The command mnemonic is MC followed by a space
•
The command instruction is BAUD followed by a space
•
There is no parameter since this is a query command
The SE4000 responds by displaying the baud rate on the remote unit.
4.3.1 Typing Remote Commands
Remote commands are not case sensitive. Commands may be entered in lower case, upper
case, or a combination of both.
4.3.2 Entering Parameter Values
Some command parameters must be enter as a numeric value, which is represented by the
pound sign <#>. If more than one pound sign is shown for a given parameter <###>, a number
must be entered for each pound sign. When a command is issued containing a numeric value,
do not type in the (#) nor the bracket <> signs. Enter only the numerical value for the parameter.
4.4 Error Messages
If the SE4000 is not able to execute a command, an error message will be returned, indicating the
command was not completed. SE4000 error messages, along with the action required to resolve
the error, are listed in the following table.
Error Messages
Error Message
Explanation
Action Required
ERROR:AMBIGUOUS_LOCAL_
INSTANCE
A designator, other than a slot
designator, is required in order to
set or query the command.
For example, all audio
commands require a port
designator in order to correctly
process a command.
Issue the command using the
correct syntax, format, and
parameter.
Ensure that the appropriate
designators are included in the
command string.
ERROR:AMBIGUOUS_ SLOT
A slot designator is required in
order to set or query the
command.
For example, all audio and
auxiliary data commands require
a slot designator.
Issue the command using the
correct syntax, format, and
parameter.
Ensure that the appropriate
designators are included in the
command string.
ERROR:BAD_NUMBER_FORM
AT
The parameter number format is
incorrect.
For example, a hexadecimal
value was entered when a
decimal value is required.
Issue the command using the
correct parameter format.
ERROR:BAD_RC_INSTANCE
The command mnemonic cannot
be matched to a card ins talled in
the product..
Use the ‘?’ command to view the
current card types.
Issue the command using the
proper syntax and format.
ERROR:BAD_RESOURCE_
CONTROLLER_TYPE.
The command mnemonic is
incorrect..
Use the ‘?’ command to view the
current command mnem onics.
Issue the command using the
Содержание TIERNAN SE4000
Страница 2: ......
Страница 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Страница 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Страница 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Страница 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Страница 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Страница 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...
Страница 149: ...Table Top Rack Mount Installation Instructions SE4000 MPEG 2 Contribution Encoder E 4 01 0934 401 B...
Страница 161: ...Glossary SE4000 MPEG 2 Contribution Encoder GL 12 01 0934 401 B...