Using a Remote Unit
SE4000 MPEG-2 Contribution Encoder
4-14
01-0934-401-B
SE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
FM LOG_LIST
-
-
Query-only command; displays the fault
history log with time stamps.
For a complete description of the fault history
log, refer to the chapter on troubleshooting.
Front panel command equivalent:
Status>History>List
FM RELAY_CLR
-
-
Clears the fault relay.
Note: Clearing the fault relay does not clear
the fault history log.
Front panel command equivalent:
Status>Relay>Clear
FM RELAY_LIST
-
-
Query-only command; displays a list of faults which
trigger the fault relay.
Front panel command equivalent:
Status>Relay>List
MC BAUD
1200,2400,
4800, 9600,
19200, 38400
bps
38400 bps
Sets the asynchronous interface baud rate for the
RS-232 remote control port configuration.
Note: The SE4000 and remote terminal baud
rates must match in order for the remote
terminal and SE4000 to communicate. Once the
MC RS232_BAUD rate command is issued, the
equivalent parameter in the remote unit
software settings must be set to match the new
baud rate. However, the remote unit software
settings must not be changed before issuing
the DVB default command to the SE4000, as the
remote unit will not be able to communicate
with the SE4000.
Front panel command equivalent:
Config>Comm>Serial>Baud
MC DATA
7, 8
8
Sets the number of data bits for the RS-232 remote
control port configuration.
CM LIST
Front panel command equivalent:
Config>Comm>Serial>Data Bits
MC DATE
dd/mm/yyyy
numeric value
in the format:
mm/dd/yyyy
-
Sets the SE4000 internal date. The date is set in
mm/dd/yyyy format where:
? mm = month from 01 to 12
? dd = day of the month from 01 to 31
? yyyy = current year
For example, to set the date to June 21, 2003,
issue the command MC DATE 06/21/2003
Note: The SE4000 real- time clock does have a
battery backup source. If the unit loses power,
is turned off, or reset, the real-time clock is set
to the current (correct) day and time.
Front panel command equivalent:
Config>Control>Clock>Date
MC FLOW
Soft, Hard
Soft
Sets the remote control port flow control.
Parameters are:
? Soft = Software XON/XOFF
? Hard = Hardware RTS/CTS.
Front panel command equivalent:
Config>Comm>Serial>Flow
Содержание TIERNAN SE4000
Страница 2: ......
Страница 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Страница 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Страница 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Страница 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Страница 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Страница 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...
Страница 149: ...Table Top Rack Mount Installation Instructions SE4000 MPEG 2 Contribution Encoder E 4 01 0934 401 B...
Страница 161: ...Glossary SE4000 MPEG 2 Contribution Encoder GL 12 01 0934 401 B...