6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
99
Bandwidth
allows you to select the bandwidth
of the frequency range for the test. Available
frequency bandwidths are:
2.2 MHz, 8 MHz, 12
MHz, 17.6 MHz and 30 MHz.
Termination Resistance
lists a choice of
resistance values for the termination of the
signal.
Show hookup diagram
on test setup - If
Yes
,
the Confirmation page is prompted before
every NEXT test is started. Select
No
to hide
the diagram next time you run the test.
Hookup Diagram
button opens a
Confirmation
page displaying how to connect
your cables at the beginning of the test. When
FED is
Enabled
on the
FED Setup
page, both
the T-R/A-B and T1-R1/A1-B1 pairs will be
terminated at the FED. The hookup diagram
uses graphic and textual components.
o
Proceed
button closes the hookup
diagram prompt and starts the test.
o
Cancel
button closes the hookup
diagram prompt only.
o
The
Confirmation
window is prompted
before every
NEXT
test is started if you
selected
Yes
for the
Show hookup
diagram
. You can select
No
to hide
the diagram next time you run the test.
However, you can check the
connection diagram at any time by
pressing the
Hookup Diagram
button.
In this case, the test does not start
when you press the
OK
button to close
the
Confirmation
window.
Threshold Settings
button opens a new page
that allows you to set the
NEXT Spectrum
Threshold
.
Select Graph
button changes to
Graph
Selected
when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor
- press the left/right arrow keys
to decrease/increase the values by
moving the cursor. Press and hold the
left/right arrow keys to accelerate the
cursor. Press
to recall the cursor
and place it in the middle of the current
x-axis limits.
o
Zoom
references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
o
Pan
- use left/right arrow keys to pan
the x-axis and the up/down arrow keys
to pan the y-axis.
o
1:1
resets the x-axis and y-axis limits
to full scale.
o
Return To Test
removes these
function keys and displays the
Spectrum page.
Result
displays the pass/fail status, and test
results in graphical format.
Good
is the good threshold value for the
selected bandwidth, represented by a
horizontal green line.
Test Status
displays the current state of
measurement or an error message.
To select the parameter values: