6100-Gfast Multifunction Copper Tester Operation Manual
© 2020 Radiodetection Ltd
105
VF/AC Balance
sets the passive balance
threshold.
Type
is the threshold limit: either
Maximum
or
Minimum
.
Enabled
is a flag to use the existing threshold:
either
Yes
or
No
. For example, setting the
threshold
Enabled
to
No
will disable pass/fail
threshold.
Power Influence Threshold
displays the
Power Influence
threshold values set in
relation to
VF/AC Balance
threshold values.
To set the passive VF/AC Balance threshold values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press to confirm the value.
Passive Result Details
The
Passive Results Details
read-only page displays
the
Passive
pass/fail status,
Power Influence, VF
Noise,
and
VF/AC Balance
values.
12.3 WB Balance
The wideband balance test ensures that the balance
ratio for the twisted pair complies with applicable
standards so as to reduce the effects of common-mode
voltage to ground. The better the balance of the cable
pair, the higher the dB reading. The test measures the
WB balance at fixed and periodic frequencies
dependent on the selected bandwidth.
Balance
The
Balance
page allows you to configure the
parameters for the
WB Balance
test and view the
results, in either
Portrait
or
Landscape Mode
.
Current Group
is the current test group name,
for example
Frequency Tests
.
Current Test
displays the test being
measured. Here you can switch to another test