6100-Gfast Multifunction Network Analyzer Operation Manual
52
© 2020 Radiodetection Ltd
To navigate the results menu:
1. Press the up/down left/right arrow keys on the
keypad to select an icon.
2. Press
to display the results.
Summary
The results
Summary
page displays pass/fail status,
general and identification information, along with
comments, for the test.
General Information
displays read-only
information pertaining to the test result.
Test Lead Compensation
displays read-only
Date and Time
and
Pass/Fail Status
of the
compensated resistance and capacitance
based on the cable temperature of the test
lead.
Editable Identification Fields
display values
from the loaded file. You can edit all fields
using the editor screen or by selecting an entry
from the list box.
o
User Name/ID
o
Contractor Name
o
Test From/To
o
Job ID
o
Customer Name
o
Circuit ID
o
Comments
Function keys:
o
Save
keeps any current changes with
the current file name.
o
Save As
saves the current changes
under a different file name that you can
configure in the editor screen.
o
Don’t Save
does not save any
changes and closes the page.
o
Report
allows you to load a result file
to a USB device, update the ID fields,
and generate a report in HTML,
MHTML, or XML format.
o
Upload
(in User Auto Test only) allows
you to transfer an
Auto Test
result file
to an FTP site or USB device via the
presently selected method (Wi-Fi or
Ethernet).
To view and edit the test result information:
1. Press the up/down arrow keys to highlight and
view the desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on an editable value to open the list
box of options or the alphanumeric editor
screen. Use the navigation keys to scroll
through and select.
4. Press
to confirm the value.