- 91 -
9901.00.34DE00; 02.2017
6XEMHFWWRWHFKQLFDOPRGL¿FDWLRQV
O
PERATION
S
UPER
A
LBATROS
140 MW; S
ERIES
2
5.
3.
4.
Ź
3
.) Insert the new shear bolt from the link arm
side.
Ź
4
.) Tighten the shear bolt fastening nut
(WAF 19 mm).
Ź
5
.) Block the shear bolt nut and the pivot bolt
nut, observe the tightening torque.
Tightening torque - shear bolt
Dimension
Bolt strength
10.9
Width
across
ÀDWV
(*
DIN ISO 272)
Nm
Ib-ft
M12
137
101
19 (18*)
Tightening torques - pivot bolt
Dimension
Bolt strength
10.9
Width
across
ÀDWV
(*
DIN ISO 272)
Nm
Ib-ft
M16
338
250
24
33 R
EPLACING
THE
SHEAR
BOLT
ON
THE
SUBSOILER
Fastening
2
1
4
3
1) M16 pivot bolts
2) M16 shear bolt
3) Spring
4) M16 nut
Repair instructions
•
Always use original shear bolts.
•
Never replace shear bolts with standard bolts.
•
Replace damaged bolts with bolts of the same
strength category.
Repair
1.
3.
4.
5.
2.
Ź
1.) Undo the pivot bolt.
Ź
2.) Pivot the subsoiler in.
Ź
3.) Insert the new shear bolt from the subsoiler
side.
Ź
4.) Put the washer on and tighten the fastening
nut.
Ź
5.) Tighten the shear bolt and the pivot bolt to
the correct torque.