VTrak E-Class Product Manual
22
Configuring Cascaded Storage
Cascaded storage requires:
•
One SAS HBA card in the Host PC or Server
•
A network switch
•
A network interface card (NIC) in the Host PC or Server
To establish the data path:
1.
On the VTrak controller, connect a SAS data port or a SAS data/cascade
port to your SAS HBA card. See Figure 14.
2.
Connect the data/cascade port (a subtractive-routed port) of the first E310s
to the data port (a table-routed port) on the second E310s.
3.
Connect the remaining E310s controllers in the same manner.
You can cascade up to eight VTrak subsystems.
To establish the management path:
1.
On the VTrak controller, connect the Management Port on each Controller to
your network switch. See Figure 15.
2.
Connect the Host PC’s or Server’s standard NIC to your network switch.
Figure 14. VTrak E310s cascaded data connections
Mgmt
UPS
115200
8 N 1
Mgmt
UPS
115200
8 N 1
Mgmt
UPS
115200
8 N 1
O
I
O
I
O
I
SAS data port
E310s
SAS data/
cascade port
E310s
E310s
Host PC or Server
SAS data port
SAS data/
cascade port
SAS data port
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...