Chapter 5: Management with the CLU
167
Managing Logical Drives
The Logical Drive Management function deals with settings and functions of
existing logical drives. To create or delete a logical drive, see “Managing Disk
Arrays” on page 156. Logical drive management includes:
•
Viewing Logical Drive Information (page 167)
•
Setting an Alias for a Logical Drive (page 167)
•
Setting Write Cache Policy (page 167)
•
Setting Read Cache Policy (page 168)
•
Setting Preferred Controller ID (page 168)
•
Initializing a Logical Drive (page 168)
•
Running Redundancy Check (page 169)
•
Locating a Logical Drive (page 169)
Viewing Logical Drive Information
To view logical drive information:
1.
From the Main Menu, highlight
Logical Drive Management
and press Enter.
2.
Highlight the logical drive you want and press Enter.
The information and settings screen appears.
3.
Highlight any of the following and press Enter to view more information:
•
Check Table – Read Check, Write Check, and Inconsistency Check
Tables
•
Logical Drive Statistics
Setting an Alias for a Logical Drive
To set an alias for a logical drive:
1.
From the Main Menu, highlight
Logical Drive Management
and press Enter.
2.
Highlight the logical drive you want and press Enter.
3.
To set an alias for this disk array, highlight
Alias
and type an alias into the
field.
Maximum of 32 characters. Use letters, numbers, space between words and
underscore. An alias is optional.
4.
Press Ctrl-A to save your settings.
Setting Write Cache Policy
To set write cache policy on a logical drive:
1.
From the Main Menu, highlight
Logical Drive Management
and press Enter.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...