Chapter 8: Troubleshooting
267
Logical drive has been
placed online. Possible
data loss
One or more physical drives in the array went offline.
See page 276.
Logical drive has been set
to critical.
One or more physical drives in the array went offline.
See page 276.
Logical drive axle has
been placed online
RAID 50. One of the axles (RAID 5 arrays) returned
on online status.
Media Patrol
Media patrol is started
Result of settings or user action. Normal.
Media patrol is completed Normal.
Media patrol is paused
Media patrol paused because of user intervention,
schedule or a higher priority background activity.
Media patrol is resumed
Media patrol has resumed again after a pause.
Media patrol is stopped
Media patrol stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Media patrol is aborted
due to an internal error.
System resources are low. Reduce system load or
restart the VTrak. See page 207.
Media patrol is queued
Media patrol has been set manually or by schedule.
Media patrol is stopped
internally
Media patrol stopped because the disk array was
deleted or removed.
Online Capacity Expansion
Online capacity
expansion has started
Result of settings or user action. Normal.
Online capacity
expansion has completed
Normal.
Online capacity
expansion has paused
Expansion paused because of user intervention,
schedule or higher priority background activity.
Online capacity
expansion has resumed
Expansion has resumed again after a pause or a
reboot.
Online capacity
expansion has stopped
Expansion stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Reported Event
Corrective Action
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...