Chapter 8: Troubleshooting
263
Blowers have been
removed
Reinstall the cooling unit(s). If the blowers does not
turn, replace the blowers. See page 210.
Blowers are functioning
normally
Normal.
Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not
turn, replace the blowers. See page 210.
Blower status is unknown Check for airflow out of the cooling unit. If there is
none, check for proper installation.
Cache
BBU flushing has started
VTrak’s cache is being flushed.
BBU flushing has ended
VTrak’s cache has been flushed.
BBU flushing has failed
VTrak’s cache could not be flushed. Check your
cache flush interval setting. See page 101.
Controller
The controller
parameter(s) changed by
user
The user successfully change controller settings. See
page 101.
The controller has new
crash information
Check the event logs. See page 56.
Controller temperature is
above the threshold/
warning threshold
The VTrak controller is overheating. Check for airflow
around and through the controller, and verify that all
fans are working. Replace fans as needed.
Controller temperature is
above the critical
threshold
The VTrak controller is seriously overheating. Check
for airflow around and through the controller, and
verify that all fans are working. Replace fans as
needed.
Disk Array
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been
deleted
Result of settings or user action. Normal.
Disk array has been
added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were removed
from the enclosure.
Reported Event
Corrective Action
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...