Chapter 5: Management with the CLU
145
Locking or Unlocking the Subsystem
The lock prevents other sessions (including by the same user) from making a
configuration change to the controller until the lock expires or a forced unlock is
done. When the user who locked the controller logs out, the lock is automatically
released.
Setting the Lock
To set the lock:
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Lock Management
and press Enter.
3.
In the Lock Time field, type a lock time in minutes.
1440 minutes = 24 hours
4.
Highlight
Lock
and press Enter.
Resetting the Lock
To reset the lock with a new time:
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Lock Management
and press Enter.
3.
In the Lock Time field, type a lock time in minutes.
1 to 1440 minutes (24 hours)
4.
Highlight
Renew
and press Enter.
Releasing the Lock
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Lock Management
and press Enter.
3.
Highlight
Unlock
and press Enter.
Releasing a Lock set by another user
To release somebody else’s lock:
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Lock Management
and press Enter.
3.
Highlight
Force Unlock
and press the Spacebar to change to
Yes
.
4.
Highlight
Unlock
and press Enter.
Setting Subsystem Date and Time
Use this screen to make Date and Time settings:
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Modify System Date and Time
and press Enter.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...