Updating the Firmware in the CLU
A firmware update consists of the following actions:
•
Downloading the Firmware Image File (page 208)
•
Updating the Firmware (page 208)
•
Restarting Subsystem over a Telnet Connection (page 208)
•
Restarting Subsystem over a Serial Connection (page 209)
Downloading the Firmware Image File
Go to the Promise website at
http://www.promise.com/support
and download the
latest firmware image file to your TFTP server.
Updating the Firmware
To update the firmware file in the CLU:
1.
From the Main Menu, highlight
Additional Info and Management
, and press
Enter.
2.
Highlight
Flash through TFTP
and press Enter.
3.
Highlight
TFTP Server
and type the IP address of your TFTP server in the
field provided.
4.
Highlight
Port Number
and press the backspace key to erase the current
value, then type the new value. 69 is the default.
A list of the current users appears.
5.
Highlight
File Name
and type the file name of the firmware image file in the
field provided.
6.
Highlight
Start
and press Enter.
A message appears to tell you to reboot the VTrak.
7.
Restart the VTrak.
See “Restarting Subsystem over a Telnet Connection” on page 208 or
“Restarting Subsystem over a Serial Connection” on page 209.
Restarting Subsystem over a Telnet Connection
To restart the VTrak subsystem on a Telnet connection:
Warning
Do not restart the VTrak during a firmware upgrade procedure.
Wait until the upgrade is one and you are prompted to restart.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...