![Promise Technology E310f Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/promise-technology/e310f/e310f_product-manual_1617210133.webp)
Chapter 4: Management with WebPAM PROe
119
3.
Click the Delete tab in Management View.
4.
Check the box to the left of the disk array you want to delete.
5.
Click the
Submit
button.
6.
In the confirmation box, type the word confirm in the field provided.
7.
Click the
OK
button.
The selected disk array disappears from the Disk Array List the Information tab.
Viewing Disk Array Information
To view Disk Array information:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
The disk array information is shown in Management View.
Disk Array Operational Status
•
OK – This is the normal state of a logical drive. When a logical drive is
Functional, it is ready for immediate use. For RAID Levels other than RAID 0
(Striping), the logical drive has full redundancy.
•
Synchronizing – This condition is temporary. Synchronizing is a maintenance
function that verifies the integrity of data and redundancy in the logical drive.
When a logical drive is Synchronizing, it will function and your data is
available. However, access will be slower due to the synchronizing
operation.
•
Critical/Degraded – This condition arises as the result of a physical drive
failure. A degraded logical drive will still function and your data is still
available. However, the logical drive has lost redundancy (fault tolerance).
You must determine the cause of the problem and correct it.
•
Rebuilding – This condition is temporary. When a physical drive has been
replaced, the logical drive automatically begins rebuilding in order to restore
redundancy (fault tolerance). When a logical drive is rebuilding, it will
function and your data is available. However, access will be slower due to
the rebuilding operation.
•
Transport Ready – After you perform a successful Prepare for Transport
operation, this condition means you can remove the physical drives of this
disk array and move them to another enclosure or different drive slots. After
you relocate the physical drives, the disk array status will show OK.
Adjustable Items
•
Alias – Optional.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...