Chapter 4: Management with WebPAM PROe
131
Redundancy Check can also correct inconsistencies. You can also schedule a
Redundancy Check. See “Scheduling an Activity” on page 62.
Redundancy Check a Logical Drive:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Logical Drive Summary
icon.
3.
Click the
icon of the logical drive you want to Initialize.
You can also start Redundancy check from the Subsystem
icon
Background Activities tab
4.
From the dropdown menu on the Background Activities tab, select
Redundancy Check
.
5.
To select
Auto Fix
, check the box.
This feature attempts to repair the problem when it finds an error.
6.
To select
Pause On Error
, check the box.
This feature stops the process when it finds an error.
If Auto Fix is also checked, the process stops only when it finds a non-
repairable error.
7.
Click the
Submit
button.
To view the progress of the Redundancy Check, click the Background Activity
tab.
To set Redundancy Check priority, see “Making Background Activity Settings” on
page 59.
Viewing the Logical Drive Check Table
The Logical Drive Check Table displays errors related to a logical drive. Use this
information to evaluate the integrity of the logical drive and to determine whether
corrective action is needed. To View the tables:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the Logical Drives
icon
5.
Click the Logical Drive
icon.
6.
Click the Check Table tab in Management View.
7.
Click the option for the table you want to see.
The default is All tables.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...