VTrak E-Class Product Manual
244
•
Additional capacity might appear as unpartitioned and unformatted.
At this point, you have the choice of:
•
Format the unpartitioned/unformatted capacity as a
second
logical drive
•
Delete the existing disk array and create a new one in the desired size
Delete and Recreate
If you require a logical drive larger than the maximum expansion size:
1.
Backup the data from the current logical drive.
2.
Delete the current logical drive.
See page 122 (WebPAM PROe) or page 166 (CLU).
3.
Create a new logical drive with the desired capacity.
See page 120 (WebPAM PROe) or page 165 (CLU).
4.
Restore the data to the new logical drive.
Media Patrol
Media Patrol is a routine maintenance procedure that checks the magnetic media
on each disk drive. Media Patrol checks all physical drives assigned to disk
arrays. Media Patrol does not check unconfigured drives.
Media Patrol will also check spare drives, if those drives have Media Patrol
enabled. Media Patrol for spare drives is enabled by default. You can disable it in
VTrak’s Command Line Interface (CLI).
Unlike Synchronization and Redundancy Check, Media Patrol is concerned with
the condition of the media itself, not the data recorded on the media. If Media
Patrol encounters a critical error, it triggers PDM if PDM is enabled.
You can run Media Patrol from the subsystem. See “Running Media Patrol” on
page 61 (WebPAM PROe) or page 144 (CLU).
You can also run Media Patrol on a disk array. See “Running Media Patrol on a
Disk Array” on page 124 (WebPAM PROe) or page 162 (CLU).
Current LD Size
Maximum LD
Expansion Size
Sector Size
8 to 16 TB
16 TB
4096 bytes
4 to 8 TB
8 TB
2048 bytes
2 to 4 TB
4 TB
1024 bytes
up to 2 TB
2 TB
512 bytes
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...