![Promise Technology E310f Скачать руководство пользователя страница 261](http://html.mh-extra.com/html/promise-technology/e310f/e310f_product-manual_1617210261.webp)
Chapter 7: Technology Background
247
In the example above, there is a four-drive RAID 5 disk array and a global spare
drive. Physical drives 1, 2, 3, and 4 belong to the disk array. Physical drive 5
remains unconfigured. Physical drive 6 is a revertible spare drive.
If a physical drive fails in a disk array and there is a spare drive of adequate
capacity available, the controller automatically rebuilds the array using the spare
drive. In this example, physical drive 3 failed and the array is rebuilt using
physical drive 6, the revertible spare drive.
When the rebuild is complete, the spare drive has replaced the failed drive. In this
example, failed drive 3 was replaced by spare drive 6. The disk array now
consists of physical drives 1, 2, 4, and 6.
There is no spare drive at this moment. Even if physical drive 5 is of adequate
capacity, it has not been designated as a spare, therefore the controller cannot
use it as a spare.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...