Chapter 5: Management with the CLU
151
3.
Highlight
Enclosure Settings
and press Enter.
4.
Highlight the Temperature Warning threshold you want to change.
5.
Press the backspace key to erase the current value.
6.
Type a new interval value in degrees C.
7.
Press Ctrl-A to save your settings.
Checking the Batteries
This feature enables you monitor and recondition the subsystem battery or
batteries.
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Enclosure Management
and press Enter.
3.
Highlight
Batteries
and press Enter.
4.
Highlight the battery you want to monitor and press Enter.
Battery Notes
Each battery works with a controller. If the battery is present in the subsystem but
the corresponding controller is not present, the battery will not appear in the
interface.
If a battery does not reflect normal conditions and it is not currently under
reconditioning, run the Recondition function before you replace the battery. See
“Reconditioning a Battery” on page 151.
If a battery reaches the threshold temperature while charging or discharging, the
charge or discharge pauses and the blower runs at high speed until the battery
temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the
battery. See “Replacing a Cache Battery” on page 215.
VTrak automatically reconditions the battery every two months.
When you install a new battery, the cycle count shows 0. VTrak automatically
runs a recondition on the battery to verify it. If you restart the subsystem or
controller before reconditioning is finished, the battery is charged to 100%, then
reconditioning starts again.
Reconditioning a Battery
To recondition the subsystem battery:
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Enclosure Management
and press Enter.
3.
Highlight
Batteries
and press Enter.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...