Chapter 8: Troubleshooting
279
Incomplete Array
An incomplete array can result from any of the following conditions:
•
The NVRAM watermark for the RAID level migration currently in progress is
missing or cannot be found
•
A physical drive goes missing during transport
See “Physical Drive Failed” on page 280 for more information.
When VTrak discovers an incomplete array, WebPAM PROe displays a dialog
box asking you to:
•
Click the
OK
button to accept the incomplete array
•
Click the
Cancel
button to reject the incomplete array
Before you accept the incomplete array, be sure all of the physical drives are
present and that their drive carriers are properly installed into the enclosure. See
“Installing Disk Drives” on page 13.
If you choose to accept the incomplete array:
1.
Click
OK
in the incomplete array dialog box.
2.
Check the operational status of the logical drives in the array.
•
If the logical drives are
critical
or
degraded
, proceed with a rebuild.
See “Rebuilding a Disk Array” on page 123 or page 163.
•
If the logical drives are
offline
, contact Technical Support.
See “Contacting Technical Support” on page 293
3.
Restore your data from a backup source, if required.
The CLU displays the option
Accept Incomplete Array
on the Disk Array Info and
Settings screen. Highlight the option and press Enter to accept the incomplete
array.
If you choose NOT to accept the incomplete array:
1.
Click
Cancel
in the incomplete array dialog box.
2.
Do one of the following:
•
Delete the array. See “Deleting a Disk Array” on page 118 or page 160.
•
Replace the missing physical drive.
Содержание E310f
Страница 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Страница 14: ...VTrak E Class Product Manual xiv ...
Страница 22: ...VTrak E Class Product Manual 8 ...
Страница 58: ...VTrak E Class Product Manual 44 ...
Страница 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Страница 215: ...Chapter 5 Management with the CLU 201 Shutdown complete It is now safe to power off the subsystem ...
Страница 218: ...VTrak E Class Product Manual 204 ...
Страница 228: ...VTrak E Class Product Manual 214 11 Verify that the Fan LEDs are green This completes the blower replacement procedure ...
Страница 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Страница 304: ...VTrak E Class Product Manual 290 ...
Страница 316: ...VTrak E Class Product Manual 302 ...