Page 79
59-60
29
Fine output
INT value for archive management from fieldbus
61-62
30
Fast logic output
INT value for archive management from fieldbus
63-64
31
Fine logic output
INT value for archive management from fieldbus
65-66
32
Entrance
INT value for archive management from fieldbus
67-68
33
Spill time ON
INT value for archive management from fieldbus
69-70
34
Spill time OFF
INT value for archive management from fieldbus
71-72
35
InInflight correction
INT value for archive management from fieldbus
73-74
36
Fine reactivation
INT value for archive management from fieldbus
75-76
37
Number of recipes in the
archive
INT value for archive management from fieldbus
77-78
38
Number of activities in the
archive
INT value for archive management from fieldbus
WRITING EXAMPLES
To write the Set-up parameters, follow the example below:
In bytes 1-2 (Command Register) write the value HEX 3FFF that opens the internal writing area of the
MCT 1302.
Example: You want to change the values of Set-Point 1 and Set-Point 2 to 120 and 9740 respectively.
Set-Point 1
Byte 21
Byte 22
Hex
00
78
Set-Point 2
Byte 23
Byte 24
Hex
26
0C
Save the data by writing the HEX value 7 in the Byte 1-2
N.B. The instrument does not accept writing a value equal to the value already present.