Page 29
Tolerance
The set tolerance value is checked
at the end of the batching. If the
net weight batched does not fall
within the range determined by set
+ tolerance and set - tolerance, an
error message will be displayed
until the alarm is manually silenced.
By programming the tolerance value
to 0, the control of the batched
net weight is disabled (during the
batching sequence the outputs will
not be re-connected).
Parameter used only for "activity
type”” =
AUTO DOS.
.
Numeric setup
W
eight measurement unit
2
0÷Cell capacity
0264
(MSW)
-
0265
(LSW)
Fine
reactivation
This function, if enabled, allows the
fine output to be activated again
if the batched net weight is lower
than the value set in the recipe - the
tolerance value.
Selection
YES [0] YES
[1] NO
0276
W
aiting
This parameter represents the
time that passes between the
deactivation of the outputs at the
end of the batching and the stable
weight control for the acquisition
of the net weight dosed. It is used
to wait for the fall of the flying
material. By programming the value
to zero, no timing is performed.
Parameter used only for "activity
type”” =
AUTO DOS.
.
Numeric setup
Seconds
0
0.0÷999.9
0266
Timeout
This parameter represents the
maximum time for the waiting of
the product during the batching
of a component, before the alarm
of lack of product is enabled. By
programming the zero value, no
batching check is performed.
Parameter used only for "activity
type”” =
AUTO DOS.
.
Numeric setup
Seconds
0
0.0÷999.9
0267
Coarse output
This parameter allows you to set
the fast output associated with this
activity (the same output can be
shared by several activities). By
programming this parameter to
zero, no fast output is associated
with the activity. Parameter used
in case of "activity type” =
AUTO
DOS./ MAN DOS./ TIMER /
OUTPUT.
Numeric setup
0
0÷32
0268