Page 72
0x000F Print command.
0x0010 Reading the recipe parameters.
Recipe index in MSB and
LSB
The general recipe parameters (name
and number of steps) and the parameters
related to step 1 of the recipe are read. See
registers from 0202 to 0212.
0x0011 Saving the recipe parameters.
Recipe index in MSB and
LSB
Registers 0202 to 0209 are programmed
in the recipe specified in the Data Register.
If the change also concerns the recipe
steps, the recipe steps must first be saved by
command
0x0012 Reading the recipe step.
Recipe step in LSB
The "activity” registers (0210) and the
"batching setpoint" registers (0211-0212)
are updated with the values of the step
specified in the Data Register.
0x0013 Saving the recipe step.
Recipe step in LSB
The step specified in the Data Register is
programmed with the values written in the
"activity” (0210) and "batching setpoint"
registers(0211-0212). To save the changes
in permanent memory, it is necessary to send
the command 0x0011, which can be sent
only once at the end of the recipe changes.
0x0014 Reading the activity parameters.
Activity index in LSB
See registers from 0252 to 0274.
0x0015 Saving the activity parameters.
Activity index in LSB
See registers from 0252 to 0274.
0x0016 Reading the recipe total.
Recipe index in MSB and
LSB
The total of the recipe specified in the Data
Register is read. See registers from 0301 to
0302.
0x0017 Reading the activity total.
Activity index in LSB
The total of the activity specified in the Data
Register is read. See registers from 0303 to
0304.
0x0018 Delete the recipe total.
Recipe index in MSB and
LSB
The total of the recipe specified in the Data
Register is deleted. Write 0xFFFF in the Data
Register to delete the totals of all the recipes.
0x0019 Delete the activity total.
Activity index in LSB
The total of the activity specified in the Data
Register is deleted. Write 0xFFFF in the
Data Register to delete the totals of all the
activities.
0x001A Delete recipe
Recipe index in MSB and
LSB
The recipe specified in the Data Register is
deleted.
0x001B Delete activity
Recipe index in MSB and
LSB
The recipe specified in the Data Register is
deleted.
0x001C Reset the batching alarm
-
-
0x001D Start batching.
-
-
0x001E Pause batching.
-
-
0x001F Restart batching.
-
-
0x0020 Stop batching.
-
-
0x3FFF Enabling the Output Data Area (*)
(*) The instrument parameters managed in the Fieldbus Output Data Area are not changed until this
command is sent. When the instrument is switched on, the Output Data Area is completely zeroed,
so the Fieldbus master must read the parameter values from the Input Data Area and copy them to
the relevant Output Data Area registers, and then it must send the enable command to the Command
Register. Otherwise, all the parameters managed in the Output Data Area would be reset at power
up.
(***) The instrument is in the setup phase (TRUE flag during access to the SETUP menu of the
instrument or during connection with PC software “Optimation”).