Page 58
MONOTONY [1204]
Parameter used to stabilize the weight when continuous variation of the last digit is detected. Normally
used in case of resolution of the weight exceeding 10,000 divisions or with low sensitivity of the input
signal. Value expressed in mS.
Value from 0 to 999.
Default: it depends on the value set in the Filter Value parameter
OSCILLATION TIME [1205]
Parameter used in conjunction with oscillation Range to reduce the slow and repetitive weight changes
typical in lifting systems. Enter the value of the oscillation time expressed in mS.
Value from 0 to 9999.
Default: it depends on the value set in the Filter Value parameter
OSCILLATION RANGE [1206]
As for the parameter Oscillation time, used to reduce the oscillations. Enter the value of the oscillation
expressed in weight divisions.
Value from 0 to 99.
Default: it depends on the value set in the Filter Value parameter