Page 71
TABLE C - CODING THE DIGITAL INPUTS/OUTPUTS OF EXTERNAL MODULES
BITS
31
30
29
28
26
26
25
24
Description
In 38
Out 38
ON
In 37
Out 37
ON
In 36
Out 36
ON
In 35
Out 35
ON
In 34
Out 34
ON
In 33
Out 33
ON
In 32
Out 32
ON
In 31
Out 31
ON
BITS
23
22
21
20
19
18
17
16
Description
In 30
Out 30
ON
In 29
Out 29
ON
In 28
Out 28
ON
In 27
Out 27
ON
In 26
Out 26
ON
In 25
Out 25
ON
In 24
Out 24
ON
In 23
Out 23
ON
BITS
15
14
13
12
11
10
9
8
Description
In 22
Out 22
ON
In 21
Out 21
ON
In 20
Out 20
ON
In 19
Out 19
ON
In 18
Out 18
ON
In 17
Out 17
ON
In 16
Out 16
ON
In 15
Out 15
ON
BITS
7
6
5
4
3
2
1
0
Description
In 14
Out 14
ON
In 13
Out 13
ON
In 12
Out 12
ON
In 11
Out 11
ON
In 10
Out 10
ON
In 9
Out 9
ON
In 8
Out 8
ON
In 7
Out 7
ON
TABLE D - CODING THE DIVISION AND DECIMAL VALUE
ADDRESS
DESCRIPTION
VALUES ACCEPTED
1101
Division value
1 - 2 - 5 - 10 - 20 - 50
1102
Number of decimals
0 - 1 - 2 - 3 - 4
TABELE E - CODING THE COMMAND REGISTER / DATA REGISTER
REGISTER
VALUE
COMMAND REGISTER FUNCTION DATA REGISTER FUNCTION
NOTE
0x0001 Semi-automatic zero
0x0002 Automatic tare
0x0004 Zero calibration (**)
0x0005 Full scale calibration (**)
Sample weight value in
MSW and LSW
0x0006 Analog test
Value between 0 and 100 in
intervals of 10 in LSW
0x0007 Saving data in permanent memory
0x000B Switching command from gross to
net weight
0x000C Switching command from net to
gross weight
0x000D Acquisition of zero signal (table
calibration)
0x000E Tare cancellation command.
Содержание MCT 1302