Page 32
Step number being
programmed
Alarm: total recipe
greater than the
capacity of cells
Total recipe
Activity in the archive
ENTER/EDIT RECIPE (parameters, commands)
Message
Description
Type
Units Default
Range
Fieldbus
address
Recipe
name
Alphanumeric name of the
recipe.
Alphanumeric
setup
Max. 14
alphanumeric
characters
0202-
0208
Step no.
Number of recipe steps (*)
Numeric
setup
0
0 - 20
0209
RECIPE
SETUP
It accesses the recipe
parameter setting function.
(*) In case of unloading batching, the parameter “Steps no.” must be set to 1; also in the recipe the
selected activity must be of the “UNL.DOS.” type.
ENTER/EDIT RECIPE
OPERATION KEYS
It aborts the recipe programming procedure without saving the changes
made.
It selects the previous step or the next step in the recipe.
It selects one of the activities in the archive.
Depending on the type of activity:
• Programming of the batching setpoint.
• Programming of the intermediate unloading setpoint.
• Programming of waiting time.
• Programming of outputs status.
• Programming of inputs status.
Total cancellation of recipe parameters.
It saves the recipe and returns to the main screen.