Page 78
OUTPUT DATA AREA
The following table lists the registers of the output area (written by the master and acquired by the
instrument), common to all PROFINET, ETHERCAT, ETHERNET / IP fieldbuses.
The registers have a size of 16 bits. The registers written by the master in the output area are read by
the instrument at a maximum frequency of 90 Hz (60 Hz in the case of PROFIBUS fieldbus).
The size of the Output area set in the fieldbus master must coincide with the dimension set in the instrument.
Byte
Register
address
OUTPUT AREA REGISTER
Notes
1-2
0
Command Register
See the relevant table
3-4
1
Data Register (MSW)
Value INT. - Most significant word (See Table)
5-6
2
Data Register (LSW)
Value INT. - Less significant word (See Table)
7-8
3
Monitor register
Value corresponds to the equivalent register in the input area.
9-10
4
Active recipe
INT value for archive management from fieldbus
11-12
5
Active recipe correction factor
(MSW)
Value INT. - Most significant word
13-14
6
Active recipe correction factor
(LSW)
Value INT. - Less significant word
15-16
7
Batching cycles
INT value for archive management from fieldbus
17-18
8
Recipe/activity name
(chara character02)
INT value for archive management from fieldbus
19-20
9
Recipe/activity name
(chara character04)
INT value for archive management from fieldbus
21-22
10
Recipe/activity name
(chara character06)
INT value for archive management from fieldbus
23-24
11
Recipe/activity name
(chara character08)
INT value for archive management from fieldbus
25-26
12
Recipe/activity name
(chara character10)
INT value for archive management from fieldbus
27-28
13
Recipe/activity name
(chara character12)
INT value for archive management from fieldbus
29-30
14
Recipe/activity name
(chara character14)
INT value for archive management from fieldbus
31-32
15
Number of receipt steps
INT value for archive management from fieldbus
33-34
16
Recipe/activity steps
INT value for archive management from fieldbus
35-36
17
Recipe step, batching setpoint
(MSW)
Value INT. - Most significant word for archive management from
fieldbus
37-38
18
Recipe step, batching setpoint
(LSW)
Value INT. - Most significant word for archive management from
fieldbus
39-40
19
Type of activity
INT value for archive management from fieldbus
41-42
20
Fine (MSW)
Value INT. - Most significant word for archive management from
fieldbus
43-44
21
Fine (LSW)
Value INT. - Most significant word for archive management from
fieldbus
45-46
22
Inflight (MSW)
Value INT. - Most significant word for archive management from
fieldbus
47-48
23
Inflight (LSW)
Value INT. - Less significant word
49-50
24
Tolerance (MSW)
Value INT. - Most significant word
51-52
25
Tolerance (LSW)
Value INT. - Less significant word
53-54
26
Waiting time
INT value for archive management from fieldbus
55-56
27
Product timeout
INT value for archive management from fieldbus
57-58
28
Fast output
INT value for archive management from fieldbus