Page 42
The following pages describe all the parameters that can be set. At the end of the description of each
parameter, if any, the fieldbus address corresponding to the parameter is shown. If the parameter is of
the selectable type, the value to be entered in the register for the desired selection is indicated between
“[ ]”.
CALIBRATION MENU
MEASUREMENT UNIT
Measurement unit related to the weight value; it appears on the main screen and in all weight para-
meter settings.
Selectable values:
[0] kg, [1] g [2] t [3]
lb, [4] N, [5] kN
Default: kg
DIVISION VALUE [1101÷1102]*
Value of a single division, expressed in the chosen measurement unit. The relationship between the
system’s capacity and the division value constitutes the resolution of the system (number of divisions).
Following the change in the division value, if the system capacity is not changed, the weight calibration
is automatically corrected.
Selectable values:
0.0001 - 0.0002 - 0.0005
0.001 - 0.002 - 0.005
0.01 - 0.02 - 0.05
0.1 - 0.2 - 0.5
1 -2 - 5
10 - 20 - 50
Default: 1
(*) The setting of the division values via fieldbus takes place differently from that made by the instrument.
Refer to the 1101 and 1102 addresses of the MODBUS register table.
LOAD CELLS CAPACITY [1103-1104]
It defines the value corresponding to the sum of the nominal capacity of the load cells expressed in the selected
measurement unit. In the case of systems with only one load cell and “N” fixed supports, enter the value of the
cell capacity for the total number of supports. This data constitutes the full scale value of the weighing system.
Following the change of the parameter value, the theoretical weight calibration is recalculated.
Values: from 0 to 999999
Default: 0
LOAD CELL SENSITIVITY [1105]
Set the value corresponding to the average sensitivity of the load cells, in mV/V. Values between 0.0
and 4 mV/V are accepted. If no value is programmed, 2 mV/V is assumed.
Following the change of the sensitivity value, the theoretical weight calibration is performed.
Values: from 0.0001 to 4.0000 mV/V
Default: 2.0000