Page 73
TABLE F - CODING FOR BATCHING OPERATION
Value
Descriprion
0x0000 Batch in stop
0x0001 Batch in pause
0x0002 Batch in progress
0x0003 Batch Alarm
TABLE G - CODING FOR BATCHING STATUS
Value
Descriprion
0x0001 Coarse
0x0002 Fine
0x0003 Manual
0x0004 Wait
0x0005 Wait for acknowldgee
0x0006 Input control
0x0007 Restart
0x0008 Dump
0x0009 Error no selected formula
0x000A Error, empty formula
0x000B Formula parameters error
0x000C Maximum tare error
0x000D Capacity Error
0x000E Minimum weight error
0x000F Tolerance error
0x0010 Product timeout error
EXAMPLES
ZERO CALIBRATION
When the system is empty and stable, write the hexadecimal value 0004 in the Command Register
(0503).
To save the new value of Zero permanently in the memory, write the hexadecimal value 0007 in the
Command Register.
FULL SCALE CALIBRATION
Load the sample weight on the scale, example 1256 Kg.
Write the hexadecimal value of the sample weight 04E8 in the Data Register (0501 and 0502).
Write the hexadecimal value 0005 in the Command Register (0503).
The Command Register and the Data Register can be written simultaneously using the multiple register
function.
To save the new full scale value permanently in the memory, write the hexadecimal value 0007 in
the Command Register.