Parker Hannifin Corporation
Parflex Division
Ravenna, Ohio
Bulletin No. 4660-PGP2T
Parflex
®
Flexible Gas Piping System
Design and Installation Guide
Outdoor Appliances
•
Permanently mounted grills, appliances and gas lights located on exterior decks should be con-
nected to the Parflex system following manufacturer’s instructions. Exposed Parflex tubing should be
supported against deck joists. If the deck elevation is below the top of the foundation or if the tubing
is subject to contact, the tubing should be protected in weather-tight nonmetallic conduit. Building
penetrations must be sealed to comply with all local codes.
Section 4.0 Installation Practices
Exterior Infrared Heaters
• Infrared heaters rigidly mounted on interior/exterior walls or ceilings must be connected to the
Parflex system in compliance with local codes and in accordance with manufacturer’s instructions. The
Parflex CSST should be mounted to the fixed end of the heater to avoid expansion and contraction that
occurs.