5-16
Functions
5
The feed velocity during a move becomes the commanded velocity multiplied by the velocity override value.
If the velocity override value is changed during a move, the moving part is accelerated at the same acceleration
profile and acceleration as the normal acceleration time when the velocity override value is increased. In the
same way, the moving part is decelerated at the same deceleration profile and deceleration as the normal
deceleration time when the velocity override value is decreased.
[Acceleration: s-shaped, deceleration: constant acceleration]
Waiting for trigger
500ms/div
NORM:2kS/s
150%
100%
0%
Waiting for trigger
500ms/div
NORM:2kS/s
150%
100%
0%
[Related parameters]
#3
Selecting the type of cam profile move
#4
Selecting the acceleration type
#5
Selecting the deceleration type
#7
Acceleration time during a trapezoidal move
#8
Deceleration time during a trapezoidal move
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...