1-9
[Details of Setting Switches and Status Display LEDs]
SRV-DS Servo disable switch
The servo is turned off for as long as this switch is pressed, regardless
of the command status of the RS232C interface and PLC interface.
When the power is turned on, the operation status of the driver is
determined by the status of these switches.
bit1
Reset all
If this bit is on when the power is turned on, all driver
information is reset to the default status at shipping.
bit2
Reserved
bit3
Reserved
bit4
Maintenance operation setting
If this bit is on when the power is turned on, the driver is set
in maintenance operation status. Normally, this bit should be
set to off.
PSW1
Piano switch
bit1
Test operation
Starts test operation when the lever is up.
Ends test operation when the lever is down.
bit2
RS-232C operation enable
Enables or disables the following
commands from the RS-232C interface
depending on the status when the power is
turned on.
Commands to be disabled: @1 Abort
@2 Stop
@3 Stop
@11 Jog
Lever up:
Enable
Lever down: Disable
CN4
Controller interface connector
Error display LED
Displays an error code when an error occurs.
When resetting:
"0" (lit)
When operating:
"." (flashing)
Check terminal
0
9
8
7
6
5
4
3
2
1
ON
V
V
V
A
B
C
GND
TB1
RS ID
SRV DS
SW1
1
4
MOTOR
GND
LINE
200-
230VAC
RS EN
COIN
ZERO
GND
TEST
- CN4 -
- TB2 -
1
7
- CN3 -
- CN2 -
RS232C
- CN1 -
COIN
AXIS
BUSY
CRDY
SRDY
ERR
RS-ID Rotary switch
SW1 Slide switch
Status display LEDs
CRDY
CPU ready
Indicates that the driver finished its initial
processing and went into its normal status.
SRDY
Servo ready
ERR
Error status
BUSY
Busy
Indicates that the driver is currently
operating.
AXIS
Axis is operating Indicates that the axis is currently operating
(dwell operation)
COIN
Settling status
Indicates that the axis is in its position
settling status.
The communication method of the RS232C interface is set according
to the status of this switch when the power is turned on.
0
Single channel communication
1 to 9
Multi-channel communication. The value corresponds to
the ID of the slave station.
COIN
Settling
Indicates that the axis is in its position settling
status.
ZERO
Zero signal status
(LED display indicates the Zero signal status.)
GND
Digital ground
1
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...