4-15
(3) Click Auto Tuning Start (tuning starts).
(4)
Follow the message on the dialog box and click “OK” to start the auto-tuning operation.
Caution
The rotor rotates a maximum of 30º (seven times of reciprocating operation) in the CW
direction. The operation width varies depending on the velocity rating of the motor.
Take extra care not to cause any mechanical interference around the rotor.
<How to calculate the operation width>
Operation width (degree) = motor velocity rating [rps] x 0.02 x 360
(5) Each parameter setting value is displayed and the auto-tuning is automatically terminated.
!
!
!
!
4
Click the Auto Tuning
Start button
After the auto-tuning is
performed, the set values
are displayed.