204
Command pulse type
While in machine setting mode
Minimum value:
0
Maximum value:
2
Initial value:
2
Unit:
None
Long:
Short:
CmdPlsType
CmdPlsType
Specify the position command pulse type.
0: PUA_IN:UP, SDB_IN:DOWN
1: PUA_IN:A, SDB_IN:B
2: PUA_IN:PLS, SDB_IN:SIGN
205
Monitor pulse type
While in machine setting mode
Minimum value:
0
Maximum value:
1
Initial value:
1
Unit:
None
Long:
Short:
MonPlsType
MonPlsType
Specify the position monitor command pulse type.
0: UA_OUT:UP, DB_OUT:DOWN
1: UA_OUT:A, DB_OUT:B
206
Enabling current limit external input
While in machine setting mode
Minimum value:
0
Maximum value:
1
Initial value:
0
Unit:
None
Long:
Short:
ExtCurLmtEn
ExCurLmtEn
Specify whether or not to perform a current limit according to the current limit external input signal.
0: Do not perform.
1: Perform.
207
Simplified scaling weighted data
While in machine setting mode
Minimum value:
1
Maximum value:
64
Initial value:
4
Unit:
None
Long:
Short:
CmdWeight
CmdWeight
Specify how many pulses a single command unit equals to during a simplified scaling operation. Specify in a power of
2 (e.g., 1, 2, 4, 8, …).
213
Axis maximum velocity
While in machine setting mode
Minimum value:
1
Maximum value:
16000000
Initial value:
Motor dependent
Unit:
Axis command unit/sec
Long:
Short:
Vmax
Vmax
Specify the maximum velocity during operation. The actual maximum velocity is determined by the smaller value of
this parameter or the maximum velocity [axis command unit/sec] converted from the maximum velocity [rps, mps]
determined by the motor and driver. This maximum velocity value is displayed on the monitor.
218
Enables error when over-load occurs
While in machine setting mode
Minimum value:
0
Maximum value:
1
Initial value:
1
Unit:
None
Long:
Short:
OverloadErrorEn
OVL_ErrEn
Specify whether or not to process as an error when over-load occurs.
0: Does not process as an error.
1: Processes as an error.
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...