Error number
5
Kernel error
Error type:
[KIND_SYS] System error
Measures:
[TYPE_ELS] Others
Long:
Short:
KernelError
KernelErr
Main cause:
An error that should have not occurred in driver software has occurred.
[Subcode]
1: Axis operation handshake error
2: System program error
Action to take:
Contact us.
Error number
10
Data sum error
Error type:
[KIND_POR] Start-up error
Measures:
[TYPE_POR] Do not start up.
Long:
Short:
DataSumError
DataSumErr
Main cause:
Destroyed data was detected during data check when the power was turned on.
[Subcode]
1: Parameter file
2: Parts data file
3: Program file
4: Index correction file
5: I/O logic setting file
6: Index file Type B
7: Absolute accuracy compensation file
Action to take:
Perform the Reset All operation, and download all backup data.
Error number
11
Data error
Error type:
[KIND_POR] Start-up error
Measures:
[TYPE_POR] Do not start up.
Long:
Short:
DataError
DataError
Main cause:
Data that cannot be processed was detected when the power was turned on.
[Subcode]
1: Basic data and adjustment data problem
2: Servo constant problem
Action to take:
Contact us.
Error number
15
Encoder error
Error type:
[KIND_SYS] System error
Measures:
[TYPE_SRV] Servo OFF
Long:
Short:
EncoderError
EncoderErr
Main cause:
An encoder and revolver signal problem was detected.
[Subcode]
1: No SIG0 signal edge
2: No SIG1 signal edge
3: SIG0 signal cycle problem
4: SIG1 signal cycle problem
Action to take:
Contact us.
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...