3-9
3.6
Wiring of Controller Cable
<CN4> terminal
Pin #
Signal name
Pin #
Signal name
Pin #
Signal name
Pin #
Signal name
1 COMP1
10 UA_OUT-
19 IN_ERR_RESET
28 IN_FN
2 COMN1
11
20 IN_SERVO
29 IN_PLS_DIRECT
3 OUT_DRDY
12 DB_OUT-
21 IN_MODE_START
30 IN_PACT
4 OUT_SRDY
13 Z_OUT+
22 IN_ABORT
31 (NC)
5 OUT_BUSY
14 Z_OUT-
23 IN_MODE.0
32 (NC)
6 OUT_XOVL
15
24 IN_MODE.1
33 CRNT
7 OUT_OVER
16 PUA_IN-
25 IN_POSW.0
34 CRNT_LMT_IN-
8 OUT_COIN
17
26 IN_POSW.1
35 (NC)
9
18 SDB_IN-
27 IN_GAIN
36 (NC)
Electric wire
specification
!
0.2 to 0.5 mm2 or more, multiple-core batch shielded cable, 3 m or
less in length
!
Optional cable: CP4202G-
"""
19
36
18
1
3
2
1
18
36
21
20
19
Insertion surface
Chassis ground
(shielded cable)
Soldering surface
Terminal for <CN4>
Made by Honda Tsushin Kogyo
Connector: PCR-S36FS
Housing: PCR-LS36LA