2-3
2.2
Installation of the Driver
The standard installation method for the driver is either to mount it on a rack or a wall.
(1) Installation Position
!
If there is a heating source near by, the temperature should be prevented from increasing by installing a
shielding cover, etc.; the temperature around the driver should not exceed 50
°
C (Note 1).
!
If there is a source of vibration near by, the rack should be installed via a vibration absorption material.
!
In addition to the above, it should be avoided to install the driver in surroundings that are high in
temperature and humidity, filled with dust, metal powder, corrosive gas, etc.
(2) Installation Method
!
The standard way of installation is to install the driver on a rack, aligning the top and bottom with the
front panel in the front. Do not put the panel surface into a sideways position or upside down (see the
figure below).
!
The driver box employs a natural air ventilation system. Make sure to secure space for ventilation above
and below (25 mm or more) and right and left (25 mm or more) (see the figure below).
!
Make sure to use the installation holes (four places) of the upper and lower brackets at installation.
25 mm
25 mm
Should not be installed in a
sideways position.
Should not be
installed
upside down.
(Note: 1)
2 kW level drivers, but not other types, will have the current characteristics shown in the graph below as a
function of the ambient air temperature during operation. Therefore, it is recommended to use the driver in an
ambient air temperature of 40
°
C or less in order to prolong its life.
0%
Ambient air temperature during operation
Square current duty
40
℃
50
℃
60
℃
Current derating curve
10%
20%
30%
40%
50%
25%
45%
10
℃
20
℃
30
℃
0
℃
2
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...