3-3
3.2
Cable Specification List
Cable name
Electric cable size
Driver
Current (A)
1)
AC power supply
cable
2.0 mm
2
or more, 30 m or less in length
TB1
*
2)
Ground cable (power
supply)
2.0 mm
2
or more
TB1
*
3)
Motor cable
2.0 mm
2
or more, 30 m or less in length
TB1
*
4)
Sensor brake cable
0.3 to 0.75 mm
2
TB2
5)
RS232C
communication cable
Dedicated cable is required.
CN1
6)
Encoder resolver
cable
0.2mm
2
twisted pair, batch shielded cable, outer
diameter
φ
14 mm or less, 10 m or less in length
CN2
Maximum
100 mA DC
7)
Jumper cable
2.0 mm
2
or more
TB1
*
8)
Analog monitor card
Dedicated cable is required. [R7033YB] (cable
with connector)
CN3
9)
Controller cable
0.2 to 0.5mm
2
, batch shielded cable, outer
diameter
φ
9 mm or less, 3 m or less in length
CN4
Maximum
500 mA DC
*
20A for the A (
φ
264mm) and E (
φ
205mm) types for both the DM and DR series
15A for the B (
φ
160mm) type, and 10A for the DM1004B/1004C motors
3
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...