7-5
[Transmission character string]
Transmission character strings are classified as follows. The details about the @ commands and parameter
commands will be explained separately in Section 7.4, “@ Commands” and Section 7.5, “Parameter
Commands.”
Explanation
Receivable status
@ commands
Commands for operating the driver
Receivable status changes
depending on the command.
Parameter
commands
Commands for setting parameters and
reading parameter/monitor values.
Receivable status changes
depending on the parameter.
[Response character string]
A response character string is structured as follows.
: Field 1
Response
character string
Prompt
: Field 2
...
: Field 3
Space, one character
Header
Response character strings are classified as follows.
Header
structure
!
part
"
part
Explanation
General
R
!"
Number of
fields
For the field expression
method; see the note.
Normal response character strings to a
transmission character string.
The number of fields changes depending on
the content of the response.
Error
ERR
!!
.
"
Alarm
ALM
!!
.
"
Error/alarm
code (main)
Error/alarm code (sub)
Response character string to a transmission
character string at error and alarm.
Fields never exists.
Note: In case of a general response the
"
part of the field is expressed in one of the following ways:
0: In case there is no field
D: Character string expressed in decimal
B: Binary expression (8, 16, 32 digits)
H: Hexadecimal expression (2, 4, 8 digits)
S: Character string
Z: Other than above (character string, etc.)
The following shows some examples of response character strings.
R00
R1D
Position control bandwidth: 12
R1B
Sensor group signal status: 00010000
ERR30.0
Servo not ready
ALM60.0
Cannot interpret command
7
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...