229
Excessive position deviation error processing type
While in machine setting mode
Minimum value:
0
Maximum value:
5
Initial value:
1
Unit:
None
Long:
Short:
OverSpeedErrorType
OVPeErrTyp
Specify the processing type when an excessive position deviation error occurs.
When operating the built-in controller axis:
0: Maintains the servo status after the axis operation stops (low level).
1: Turns the servo OFF after the axis operation stops (low level).
2: Stops the axis operation (low level) and turns the servo OFF immediately.
3: Maintains the servo status after the axis operation stops (high level).
4: Turns the servo OFF after the axis operation stops (high level).
5: Stops the axis operation (high level) and turns the servo OFF immediately.
When performing the higher controller follow-up:
0: Switches to the built-in controller, and maintains the servo status after a deceleration stop.
1: Switches to the built-in controller, and turns the servo OFF after a deceleration stop.
2: Switches to the built-in controller, performs a deceleration stop, and turns the servo OFF immediately.
3: Switches to the built-in controller, and maintains the servo status after an immediate stop.
4: Switches to the built-in controller, and turns the servo OFF after an immediate stop.
5: Switches to the built-in controller, performs an immediate stop, and turns the servo OFF immediately.
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...
Страница 147: ...11 12 Specifications 11 3 U K 2kW level with regenerative unit ...