10-4
Maintenance and Inspection
10
10.4.2 Restore Operation
The restore operation uses either of the backup data that was copied to a file via the PC utility or that was copied
to the driver’s built-in flash ROM. Perform either of the following restore operations:
[Restore using the PC utility]
Using the PC utility, restore the backed up driver memory contents to an electronic file in the personal computer
to the driver. Perform the following restore operation using the PC utility:
•
Parameters download
•
Programs download (batch)
•
Index equal division compensation download (batch)
•
Index unequal division download (batch)
•
Parts download (batch)
•
I/O settings download
[Restore from the driver’s built-in flash ROM]
Restore the driver memory contents from the on-board flash ROM by copying the driver memory contents to the
driver’s built-in flash ROM in a batch operation.
Set the slide switch on the front panel as shown in the figure below, and turn ON the power. When the CRDY
lamp flashes after several seconds, the restore operation is completed.
CRDY: LED that flashes when backup is properly completed.
ERR: LED that flashes when backup is not properly completed.
SW1 slide switch
Only bit 2 and bit 4 are ON; bit 1 and bit 3 are OFF.
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...