Parameter No.
Parameter name
Minimum value
Maximum value
Initial value
Unit
Possible to change
152
First order delay compensator setting
0
3
0
None
Always
153
Notch filter: Frequency 1 selection
50
1500
1500
Hz
Always
154
Notch filter: Frequency 2 selection
50
1500
1500
Hz
Always
155
Load inertial/load mass
0
200000
0
1/1000kgm
2
or
1/1000kg
Always
201
Selection of English/Japanese display
0
1
0
None
While in machine
setting mode
202
Coordinate (+) direction setting
0
1
1
None
While in machine
setting mode
203
Using position current value filter
0
1
Motor dependent
None
While in machine
setting mode
204
Command pulse type
0
2
2
None
While in machine
setting mode
205
Monitor pulse type
0
1
1
None
While in machine
setting mode
206
Enabling current limit external input
0
1
0
None
While in machine
setting mode
207
Simplified scaling weighted data
1
64
4
None
While in machine
setting mode
213
Maximum velocity
1
16000000
Motor dependent
Axis command
unit/sec
While in machine
setting mode
218
Enables error when over-load occurs
0
1
1
None
While in machine
setting mode
219
Velocity feedback filter use
0
1
0
None
While in machine
setting mode
220
Velocity feedback filter bandwidth
50
1000
1000
Hz
While in machine
setting mode
221
Velocity command filter bandwidth
50
1000
1000
Hz
While in machine
setting mode
222
Enables error when over-speed occurs
0
1
1
None
While in machine
setting mode
224
Enables error when excessive position
deviation occurs
0
1
1
None
While in machine
setting mode
227
Over-speed error processing type
0
2
1
None
While in machine
setting mode
228
Over-load error processing type
0
2
1
None
While in machine
setting mode
229
Excessive position deviation error
processing type
0
2
1
None
While in machine
setting mode
Содержание Dynaserv G2
Страница 1: ...Effective March 1 2002 p n 88 020389 01 A Automation Dynaserv G2 Drive User Guide ...
Страница 22: ...2 1 Chapter 2 Installation 2 1 Installation of the Motor 2 2 Installation of the Driver ...
Страница 146: ...11 11 3 Driver Section 1 U A B 500W Type B is shown in the figure 2 U L 2kW level without regenerative unit 11 ...